Quantity
|
Out of stock
|
||
|
|
|||
Cables, Holders and Adapters for HFE Units
Cables, holders and adapters are important components of an electrosurgical system and provide the connection between working instruments and a compatible high-frequency electrosurgical unit.
The Nadiya-4.com catalogue includes monopolar electrode holders, bipolar forceps holders, connecting cables, and adapters for laparoscopic instruments. Individual models differ by instrument type, shank diameter, cable length, design, and connection method.
When selecting an accessory, it is important to check its compatibility with both components of the system: the electrosurgical unit and the working instrument.
Б-008 Connecting Cable for Bipolar Clamps and Scissors
The Б-008 connecting cable is intended for connecting compatible bipolar clamps or scissors to a high-frequency electrosurgical unit.
- intended for: bipolar clamps and scissors;
- cable length: 3 m;
- plug: Ш4.
Before ordering, check the electrosurgical unit model, the type of bipolar instrument, and connector compatibility.
Adapters for Monopolar Laparoscopic Instruments
A monopolar laparoscopic adapter is used to connect a compatible monopolar laparoscopic instrument to an electrosurgical system.
Б-009 Adapter for a Monopolar Laparoscope
The Б-009 adapter is intended for connecting a monopolar laparoscopic instrument to a compatible electrosurgical unit.
- plug: Ш4;
- connection diameter: 3.2 mm.
The catalogue also includes another version of the monopolar laparoscopic adapter with a 4 mm connection diameter, available to order.
Monopolar Electrode Holders
A monopolar electrode holder is used to hold an active electrode and connect it to a compatible high-frequency electrosurgical unit.
The catalogue includes electrode holders with different shank diameters:
The shank diameter is one of the key compatibility parameters. The electrode must match the design and shank diameter supported by the specific holder.
Б-0052 Reusable Monopolar Electrode Holder
The Б-0052 monopolar electrode holder is intended for electrodes with a 2.4 mm shank diameter. The holder features control buttons for activating modes supported by the compatible electrosurgical unit.
- electrode shank diameter: 2.4 mm;
- cable length: 3 m;
- plug: Ш4;
- version: reusable;
- control: buttons on the holder body.
The catalogue also includes a single-use 2.4 mm electrode holder with control buttons.
Holders for Bipolar Forceps
The catalogue includes suitable connecting holders for compatible bipolar forceps. Reusable and selected single-use versions are available.
For example, the Б-007 bipolar electrode (forceps) holder has a 3 m cable and a Ш4 plug.
Before selecting a holder, check the type of bipolar instrument, its connection design, and compatibility with the output of the specific electrosurgical unit.
Cables for Neutral Electrodes and Other Instruments
Some electrosurgical instruments and electrodes require a dedicated connecting cable. The category includes, among others:
- cable for the Б-0031 single-use passive (neutral) electrode, 3 m long;
- cable for monopolar scissors, 3 m long with a Ш4 plug;
- Б-008 cable for bipolar clamps and scissors.
The cable should be selected for the specific type of instrument. An identical or similar plug shape does not automatically mean electrical or functional compatibility.
How to Choose a Cable, Holder or Adapter for an HFE Unit
Before ordering, we recommend checking:
- the exact electrosurgical unit model;
- the type of working instrument;
- the connector type and configuration;
- the electrode shank diameter when selecting an electrode holder;
- the connection diameter when selecting a laparoscopic adapter;
- whether control buttons on the holder are required;
- single-use or reusable design;
- the condition of the existing cable, plug, and contacts if the component is being purchased as a replacement.
We do not recommend selecting accessories based only on the visual appearance of the connector. If the exact model is unknown, provide the unit name, instrument SKU, and photographs of the connectors to help verify compatibility.
Compatibility of the Electrode, Holder, Cable and HFE Unit
An electrosurgical system consists of several interconnected components. For example, when using a monopolar electrode, it is necessary to check the compatibility of the electrode itself, the holder shank diameter, cable, unit connector, and other required components of the system.
For bipolar instruments, compatibility between the bipolar forceps or clamp, connecting cable, and bipolar output of the electrosurgical unit must be checked.
Suitable working instruments are available in the Monopolar Interchangeable Electrodes and Bipolar Interchangeable Instruments sections.
Checking Cables and Holders Before Use
Before use, check the condition of the cable, insulation, plugs, contact parts, and holder body. Reusable components should be cleaned, reprocessed, and operated in accordance with the documentation for the specific product.
- do not use a cable with damaged insulation;
- check plugs and contact parts;
- do not use incompatible adapters;
- check that the electrode is securely fixed in the holder;
- do not use damaged or deformed components;
- follow the documentation requirements for reusable products and reprocessing.
The information on this category page does not replace the official documentation for the specific accessory and electrosurgical unit.
Frequently Asked Questions
How do I choose a holder for a monopolar electrode?
Check the electrode shank diameter, connector type, electrosurgical unit model, and required control method. The catalogue includes holders for 0.8, 2.0, and 2.4 mm electrodes.
Can I use a cable from another electrosurgical instrument?
The cable should be selected according to the specific instrument and electrosurgical unit. Similar-looking plugs do not guarantee electrical or functional compatibility.
What is a monopolar laparoscopic adapter used for?
The adapter is used to connect a compatible monopolar laparoscopic instrument to an electrosurgical system. The connector type and connection diameter should be checked before selection.
What is the difference between 0.8, 2.0, and 2.4 mm monopolar electrode holders?
The main difference is the electrode shank diameter. The holder should be selected according to the shank diameter of the specific electrode. Some 2.4 mm models are also equipped with control buttons.
Buy Cables, Holders and Adapters for HFE Units
Nadiya-4.com offers connecting cables, electrode holders, and adapters for compatible high-frequency electrosurgical units and instruments.
If you are unsure about compatibility, provide the specialist with the electrosurgical unit model, instrument name or SKU, and, if possible, photographs of the connectors. We will help check compatibility and select the appropriate component.